Chapter 2
Message and Recovery Procedures
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message ILPOWER-3-ILPOWER_INTERNAL_IF_ERROR: Inline Power internal error,
interface [chars]: [chars].
Explanation
second [chars] describes the error.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
"Error Message Traceback Reports" section on page
Error Message ILPOWER-3-SHUT_OVERDRAWN: Interface [chars] is shutdown as it is
consuming more than the maximum configured power ([dec]) milliwatts.
Explanation
allocation. [chars] is the port, and [dec] is the maximum configured power.
Recommended Action
the powered-device specifications or ratings. We recommend configuring the cutoff power to a value
higher than the required power for the device.
Error Message ILPOWER-4-LOG_OVERDRAWN: Interface [chars] is overdrawing power. it is
consuming [dec] milliwatts where as maximum configured power is ([dec])
milliwatts.
Explanation
interface. The power budgeting calculations determined by the switch are no longer valid, and you
might risk overloading the switch. [chars] is the interface, and [dec] is the maximum configured
power.
Recommended Action
powered-device electrical specifications or ratings. We recommend that you change the cutoff power
value.
Error Message ILPOWER-5-CLR_OVERDRAWN: Interface [chars] is NOT overdrawing power.
it is consuming [dec] milliwatts where as maximum configured value is ([dec])
milliwatts.
Explanation
power allocation. [chars] is the interface. The first [dec] is the power being consumed, and the
second [dec] is the maximum allocated power value.
Recommended Action
OL-9772-05
A software check failed during PoE processing. The first [chars] is the interface. The
Copy the message exactly as it appears on the console or in the system log.
The interface is shut down because it is consuming more than the maximum power
Ensure that the cutoff-power value is configured for the device and is based on
The powered device is drawing more power than the maximum power configured on the
Ensure that the correct power is budgeted for this interface based on the
The device connected to the PoE interface is consuming less power than the maximum
No action is required.
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
1-7.
1-7.
ILPOWER Messages