Cisco Catalyst 3750-X Message Manual page 76

Hide thumbs Also See for Catalyst 3750-X:
Table of Contents

Advertisement

PLATFORM_ENV Messages
Error Message PLATFORM_ENV-1-RPS_PS_MISMATCH: [chars].
Explanation
Recommended Action
Error Message PLATFORM_ENV-1-RPS_PS_SIGNAL_FAULTY: [chars] signal on RPS power
supply [chars] is faulty.
Explanation
PoE), and the second [chars] is the power supply ID (A or B).
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_ENV-1-RPS_PS_THERMAL_CRITICAL: RPS power supply temperature
has reached critical threshold.
Explanation
normally.
Recommended Action
temperature.
Error Message PLATFORM_ENV-1-RPS_STANDBY: [chars].
Explanation
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_ENV-1-RPS_SYS_POWER_BAD: [chars].
Explanation
provide power to the switch. [chars] is the error message.
Recommended Action
replace the power supplies.
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
2-58
The power supplies in the RPS 2300 are incompatible. [chars] is the error message.
Remove one of the power supplies, or use compatible power supplies.
The specified RPS 2300 has a faulty signal. The first [chars] is the signal value (12V or
Copy the message exactly as it appears on the console or in the system log.
The power supply in the RPS 2300 has reached the critical threshold. It cannot function
The external temperature is too high. Immediately reduce the room
A faulty RPS 2300 is detected. [chars] is the error message.
Copy the message exactly as it appears on the console or in the system log.
The RPS 2300 system power state changed to bad. The RPS 2300 might not be able to
Check the power supplies in the RPS 2300. If the message appears again,
Chapter 2
Message and Recovery Procedures
1-7.
1-7.
"Error
"Error
OL-9772-05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3560-xCatalyst 3560-eCatalyst 3750-e

Table of Contents