Cisco Catalyst 3750-X Message Manual page 93

Hide thumbs Also See for Catalyst 3750-X:
Table of Contents

Advertisement

Chapter 2
Message and Recovery Procedures
Error Message PLATFORM_STACKPOWER-4-SSLS_EVENT: Switch [dec] experienced a system
star load shed event
Explanation
member number. One example of an SSLS event is a situation in which a switch is physically
removed from the power stack by a cable removal and that switch is a sourcing system in a star
topology.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_STACKPOWER-4-UVLS_EVENT: Switch [dec] experienced an under
voltage load shed event
Explanation
number.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_STACKPOWER-4-REDUNDANCY_LOSS: Switch [dec]...[dec] power
stack lost redundancy and is now operating in power sharing mode
Recommended Action
sharing mode. [dec] ... [dec] are the stack member numbers that operate in power sharing mode.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_STACKPOWER-4-BISP: Switch [dec] experienced a BISP event
Explanation
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
OL-9772-05
The switch shut down because of a system star load shed (SSLS) event. [dec] is the stack
Copy the message exactly as it appears on the console or in the system log.
The switch shut down because of a low-voltage condition. [dec] is the stack member
Copy the message exactly as it appears on the console or in the system log.
The switch stack with this switch has lost redundancy and is operating in power
Copy the message exactly as it appears on the console or in the system log.
A built-in self protection (BSIP) event occurred. [dec] is the stack member number.
Copy the message exactly as it appears on the console or in the system log.
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
PLATFORM_STACKPOWER Messages
1-7.
1-7.
1-7.
1-7.
"Error
"Error
"Error
"Error
2-75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3560-xCatalyst 3560-eCatalyst 3750-e

Table of Contents