PLATFORM_RPC Messages
Error Message PLATFORM_RPC-3-MSG_THROTTLED: RPC Msg Dropped by throttle mechanism:
type [int], class [int], max_msg [int], total throttled [int].
Note
Explanation
was dropped. The first [int] is the message type, the second [int] is the message class, the third [int]
is the maximum number of messages that can be queued before throttling occurs, and the last [int]
is the total number of messages that have been throttled.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_RPC-3-PERSISTENT_UNABLE_TO_SEND: System is consistently
unable to send RPC message: [chars], paks_outstanding: [int].
Note
Explanation
messages. [chars] is a description of the error returned by the low-level packet-sending driver that
triggered the error (usually one of these: fifo full, fifo empty, out of buf, out of mem, null pointer,
misc failure), and [int] is the number of packets outstanding (packets from the RPC code to the driver
that have not yet been sent).
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PLATFORM_RPC-3-RESP_FAIL: Unexpected response or failure, class [dec],
req [dec], switch [dec], error [dec], [chars].
Explanation
second [dec] is the RPC request number, the third [dec] is the destination switch number, the fourth
[dec] is the returned error number, and [chars] is an optional comment.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
2-68
This message applies only to the Catalyst 3750-X and 3750-E switches.
There are too many outgoing messages queued for a message class. An RSP message
Copy the message exactly as it appears on the console or in the system log.
This message applies only to the Catalyst 3750-X and 3750-E switches.
The system is experiencing a persistent low-level transport failure in sending RPC
Copy the message exactly as it appears on the console or in the system log.
The platform received an unexpected response. The first [dec] is RPC request class, the
Copy the message exactly as it appears on the console or in the system log.
Chapter 2
Message and Recovery Procedures
1-7.
1-7.
1-7.
"Error
"Error
"Error
OL-9772-05