Redundant Power Supply; Installing The Second Power Supply Module; Required Tools; Preliminary Steps - Fujitsu PRIMERGY TX140 S1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX140 S1:
Table of Contents

Advertisement

6.3

Redundant power supply

In its basic configuration, the server has one PSU module that adjusts
automatically to any mains voltage in the range of 100 VAC to 240 VAC.
A second PSU module can be installed optionally to serve as a redundant
power supply. If one PSU module fails, the second PSU module in the
redundant configuration ensures operation can continue uninterrupted. The
failed PSU module can be exchanged without shutting down the server.
6.3.1

Installing the second power supply module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Follow the safety instructions in chapter
page
41.
6.3.1.1

Required tools

Preliminary and concluding steps: tool-less
Main steps: tool-less
6.3.1.2

Preliminary steps

Before installing the second PSU module, perform the following steps:
Ê If applicable, open the rack door as described in section
door" on page
TX140 S1
61.
Upgrade and Maintenance Manual
Power supply
"Important information" on
"Opening the rack
145