Machine Parameter J:1; Machine Parameter J:2 - Muratec MFX-1600 Field Engineering Manual

Facsimile system
Hide thumbs Also See for MFX-1600:
Table of Contents

Advertisement

Machine Parameter F:1
Initial
Switch
Setting
7
0
Adjustment of the scanning
stretching and squeezing for
6
0
ADF. (Vertical)
5
0
4
0
The plus setting stretch the
3
0
image data and the minus
2
0
setting squeeze it.
1
0
Each setting changes by
0
0
0.1%
Machine Parameter F:2
Initial
Switch
Setting
7
0
Adjustment of the scanning
stretching and squeezing for
6
0
FBS. (Vertical)
5
0
4
0
The plus setting stretch the
3
0
image data and the minus
2
0
setting squeeze it.
1
0
Each setting changes by
0
0
0.1%
Adjust
Switch 76543210
Adjust
Switch 76543210
3-15
Usage/Comments
Settings
01111111
12.7 % Maximum
:
00100000
3.2 %
:
00011000
2.4 %
:
00010000
1.6 %
:
00001000
0.8 %
:
00000000
Initial setting
:
10001000
-0.8 %
:
10010000
-1.6 %
:
10011000
-2.4 %
:
10100000
-3.2 %
:
10111000
-12.7 %
Usage/Comments
Settings
01111111
12.7 % Maximum
:
00100000
3.2 %
:
00011000
2.4 %
:
00010000
1.6 %
:
00001000
0.8 %
:
00000000
Initial setting
:
10001000
-0.8 %
:
10010000
-1.6 %
:
10011000
-2.4 %
:
10100000
-3.2 %
:
10111000
-12.7 %
Minimum
Minimum

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1200

Table of Contents