Unique Switch H:0 - Operation; Unique Switch H:1 - Operation - Muratec MFX-1600 Field Engineering Manual

Facsimile system
Hide thumbs Also See for MFX-1600:
Table of Contents

Advertisement

Unique Switch g:8

Unique Switch h:0 - Operation

Initial
Switch
Setting
7
0
First Dialing symbol when
pressing Dialing Options key
0: " "
1: " ! "
6
1
LCD error message
0: Remains in LCD
1: Returns to standby
5
1
Buzzer/keypad volume
OFF
4
0
0
0
3
0
Priority of Speed Dial / Tel
Index key
0: Speed Dial
1: Tel Index
2
0
Factory use only
1
0
Factory use only
0
0
Factory use only

Unique Switch h:1 - Operation

Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
1
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
0
RX document to polling
document
0: No
1: Yes
0
0
Factory use only
Unique Switch h:2 --- Factory use only
g:9 --- Factory use only
Adjust
When set to "0", " " will appear first when pressing
Dialing Options key.
When set to "1", " ! " will appear first.
After an error message has printed, the setting of
this switch determines if the error message will
remain in the display.
Low Medium Maximum
0
1
1
1
0
1
When set to "0", Speed Dial index will appear first
when pressing Speed Dial / Tel Index key.
When set to "1", Tel Index will appear first.
Adjust
Retrieve the document received in the memory by
polling transmission.