Machine Parameter B:5
Initial
Switch
Setting
7
0
FBS scanner registration
adjustment (Horizontal)
6
0
5
0
Adjusts the horizontal
4
0
scanning range.
3
0
The plus setting increase the
2
0
scanning range and the
1
0
minus setting decrease it.
0
0
If your machine is MFX-1200,
each setting changes by
1.4 mm.
Note: Switch 0 – 3 are not
available for MFX-1200.
Machine Parameter B:6
Initial
Switch
Setting
7
0
FBS scanner registration
adjustment (Vertical)
6
0
5
0
Adjusts the end point to scan
4
0
the document.
3
0
The plus setting increase the
2
0
scanning range and the
1
0
minus setting decrease it.
0
0
Each setting changes by
1 mm.
Adjust
Switch 7654
Max. 0011
Min. 1011
Adjust
Switch 76543210
3-10
Usage/Comments
4.2 mm
0010
2.8 mm
0001
1.4 mm
0000
Initial setting
1001
-1.4 mm
1010
-2.8 mm
-4.2 mm
Usage/Comments
Settings
01111111
255.0 mm
:
00000110
6.0 mm
00000101
5.0 mm
00000100
4.0 mm
00000011
3.0 mm
00000010
2.0 mm
00000001
1.0 mm
00000000
Initial setting
10000001
-1.0 mm
10000010
-2.0 mm
10000011
-3.0 mm
10000100
-4.0 mm
10000101
-5.0 mm
10000110
-6.0 mm
:
11111111
-255.0 mm