Memory Switch G:1 - Remote Reception - Muratec MFX-1600 Field Engineering Manual

Facsimile system
Hide thumbs Also See for MFX-1600:
Table of Contents

Advertisement

Memory Switch G:1 - Remote reception

Initial
Switch
Setting
7
0
Off-hook / on-hook detect
time (remote reception)
6
0
5
1
4
1
3
0
Off-hook / on-hook detect
time
2
1
1
0
0
0
Adjust
Sets the time interval between the off-hook/on-hook
condition for remote reception. The total time of this
time and the time specified in G:6 will be the actual
time.
Switch 7 6 5 4
Sets the time interval between the on-hook and off-
hook(or off-hook/on-hook) condition.
Switch 3 2 1 0
3-30
Usage/Comments
Time
0 0 0 0
0 ms
0 0 0 1
10 ms
0 0 1 0
20 ms
0 0 1 1
30 ms
Initial setting
0 1 0 0
40 ms
0 1 0 1
50 ms
0 1 1 0
60 ms
0 1 1 1
70 ms
1 0 0 0
80 ms
1 0 0 1
90 ms
1 0 1 0
100 ms
1 0 1 1
110 ms
1 1 0 0
120 ms
1 1 0 1
130 ms
1 1 1 0
140 ms
1 1 1 1
150 ms
Time
0 0 0 0
0 ms
0 0 0 1
100 ms
0 0 1 0
200 ms
0 0 1 1
300 ms
0 1 0 0
400 ms
Initial setting
0 1 0 1
500 ms
0 1 1 0
600 ms
0 1 1 1
700 ms
1 0 0 0
800 ms
1 0 0 1
900 ms
1 0 1 0
1000 ms
1 0 1 1
1100 ms
1 1 0 0
1200 ms
1 1 0 1
1300 ms
1 1 1 0
1400 ms
1 1 1 1
1500 ms