Muratec MFX-1600 Field Engineering Manual page 195

Facsimile system
Hide thumbs Also See for MFX-1600:
Table of Contents

Advertisement

9. Insert the PRINTER CONTROL PCB (and NIC PCB) completely and then secure it using a screw.
10.Re-attach the SHIELD PLATE.
11. Re-attach the REAR COVER.
12. Cut out the rectangular connector space for OP-100 on the OPTION COVER A. Then attach the
OPTION COVER A.
If you installed both the OP-100 and NP-200, attach the OPTION COVER B instead of the OPTION
COVER A. OPTION COVER B will be included in the NP-200 kit's carton box.
13. Connect the bi-directional parallel printer cable to the printer interface port of OP-100.
Note: Attach the ferrite core included in the OP-100's carton box to the printer cable as shown below.
Note: If using the NP-200, skip to step 14.
Option cover A
6-15
Option cover B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-1200

Table of Contents