Outdoor Unit – 2MXS18GVJU
1.6
Removal of the Coils and Thermistors
Procedure
Step
1
Remove the screw and
remove the four-way
valve coil.
2
Remove the screw and
remove the defrost
solenoid valve coil.
3
Pull out the electronic
expansion valve coil for
each room.
4
Remove the discharge
pipe thermistor.
173
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Electronic
expansion
valve coil
Fixture
Discharge pipe
thermistor
Four way
valve coil
Defrost
solenoid
valve coil
Place the thermistor so that its
end comes up to the end of
the fixture.
Be careful not to lose the
fixture for the discharge pipe
thermistor.
Thermistor
Pipe
SiUS12-928
Points
Fixture
(R10536)
Removal Procedure