Amplitude s.o.1 Applies Lfo to the Amplitude to
Amplitude s.o.2 produce Tremolo effects. This pa-
rameter determines the modulation
depth of the LFO on the Amplitude
(the output level).
The positive and negative values in-
dicate an opposed sense of increase/
decrease of the Tremolo output level
(the choice between positive or
negative values give perfectly
equivalent results).
Higher positive or negative values
increase the modulation depth.
Assignable values: –7 ... +7
0 = no effect.
Touch ampl.
Links the depth of the Amplitude
s.o.1
modulation to Aftertouch pressure,
Touch ampl.
permitting you to control of the
s.o.2
amount of Tremolo by varying the
aftertouch pressure applied to the
keys.
The "Delay" parameter is ignored
when pressure is applied to the keys
and the oscillation starts immediately.
The positive and negative values in-
dicate an opposed sense of increase/
decrease of the Tremolo output level
(the choice between positive or
negative values give perfectly
equivalent results).
Higher positive or negative values
increase the modulation depth.
Assignable values: –7 ... +7.
0 = no effect.
16•32 Reference Guide
Filter s.o.1
Applies Lfo to the Cutoff Frequency
Filter s.o.2
of the Filter (1 or 2) to produce a
"Wha-Wha" effect, caused by the
"opening" and "closing" of the Filter.
This parameter determines the
modulation depth of the Lfo on the
Cutoff Frequency.
The positive and negative values in-
dicate an opposed sense of "open-
ing" and "closing", otherwise, the
choice between a positive or nega-
tive value give perfectly equivalent
results. Higher positive or negative
values increase the Filter modulation
depth.
Assignable values: –7 ... +7.
0 = no effect.
Touch filt s.o.1 Links the depth of the Filter
Touch filt s.o.2 modulation to Aftertouch pressure.
By applying aftertouch pressure to
the keys, the "Delay" parameter is
ignored and the oscillation starts im-
mediately (toggles between open
and closed filter).
The positive and negative values in-
dicate an opposed sense of "open-
ing" and "closing", otherwise, the
choice between a positive or nega-
tive value give perfectly equivalent
results. Higher positive or negative
values increase the Filter modulation
depth.
Assignable values: –7 ... +7.
0 = no effect.