Grounding the SRX240 Services Gateway

Copyright © 2013, Juniper Networks, Inc.
Chapter 10: Connecting, Grounding, and Powering On the SRX240 Services Gateway
Place excess cable out of the way in neatly coiled loops.
Use fasteners to maintain the shape of cable loops.
Installing the SRX240 Services Gateway on page 44
Grounding the SRX240 Services Gateway on page 55
Connecting the SRX240 Services Gateway to the AC Power Source on page 49
Powering On and Powering Off the SRX240 Services Gateway on page 57
The following tools and parts are required for grounding the SRX240 Services Gateway:
Grounding cable for your services gateway—The grounding cable must be minimum
14 AWG (2 mm²), minimum 90°C wire, or as permitted by the local code.
Grounding lug—Ring-type, vinyl-insulated TV14-6R lug or equivalent for your grounding
cable
Washers and 10-32x.25-in. screws to secure the grounding lug to the protective earthing
terminal
Phillips (+) screwdrivers, numbers 1 and 2
Figure 16 on page 55
shows the SRX240 grounding point.
Figure 16: Grounding the SRX240 Services Gateway
You ground the device by connecting a grounding cable to earth ground and then attaching
it to the chassis grounding points using one M3 screw.
Table 24 on page 55
lists the specifications of the grounding cable used with the device.
Table 24: Grounding Cable Specifications for the Services Gateway
Grounding Requirement
Grounding cable
Specification
14 AWG single-strand wire cable
55