SRX240 Services Gateway Quick Start
Follow the instructions in this quick start to connect the SRX240 Services Gateway to
your network. For details, see the SRX240 Services Gateway Hardware Guide at
http://www.juniper.net/techpubs/en_US/release-independent/junos/information-products/
pathway-pages/srx-series/product/index.html.
SRX240 Services Gateway Front Panel
1
1
2
3
4
5
Callout Description
Callout
1
Mini-PIM slots
5
2
Power button
6
3
LEDs (ALARM, POWER,
7
STATUS, HA, mPIM)
4
Reset Config button
SRX240 Services Gateway Back Panel
Callout
Description
Callout
1
Cable tie holder
3
2
Power supply input
1
1
6
7
Description
Console port
Gigabit Ethernet (0/0 to 0/15) ports
USB ports
1
2
Description
Grounding point
SRX240 Services Gateway Models
The following models of the SRX240 Services Gateway are available:
Device
SRX240B
SRX240B2
SRX240H
SRX240H2
SRX240H-DC
SRX240H2-DC
SRX240H-POE
SRX240H2-POE
SRX240H-TAA
SRX240H2-TAA
SRX240H-POE-TAA
SRX240H2-POE-TAA
NOTE: On the SRX240H-POE,SRX240H2-POE, SRX240H-POE-TAA, and
SRX240H2-POE-TAA models, Power over Ethernet (PoE) of a maximum of 150 watts is
supported on all the16 ports (0/0 through 0/15).
Connecting and Configuring the SRX Series Services Gateway
Follow these instructions to connect and set up the SRX240 Services Gateway. The
LEDs on the front of the device indicate the status of the device.
Configuration Overview
The SRX240 Services Gateway requires the following basic configuration settings to
function:
Interfaces must be assigned IP addresses.
3
Interfaces must be bound to zones.
Policies must be configured between zones to permit or deny traffic.
Source NAT rules must be set.
The device has the following default configuration set when you power it on for the first
time. To use the device, you do not need to perform any initial configuration.
DDR Memory
Power over Ethernet
512 MB
No
1 GB
No
1 GB
No
2 GB
No
1 GB
No
2 GB
No
1 GB
Yes
2 GB
Yes
1 GB
No
2 GB
No
1 GB
Yes
2 GB
Yes

Advertisement

loading

Summary of Contents for Juniper SRX240B

  • Page 1 For details, see the SRX240 Services Gateway Hardware Guide at The following models of the SRX240 Services Gateway are available: http://www.juniper.net/techpubs/en_US/release-independent/junos/information-products/ pathway-pages/srx-series/product/index.html. Device DDR Memory Power over Ethernet SRX240B 512 MB SRX240 Services Gateway Front Panel SRX240B2 1 GB SRX240H 1 GB...
  • Page 2 192.168.1.1/24 If you are using this method to connect, proceed with the CLI configuration ge-0/0/15 instructions in the Getting Started Guide for the Branch SRX Series at http://www.juniper.net/techpubs/en_US/release-independent/junos/ Factory-Default Settings for Security Policies: information-products/pathway-pages/srx-series/product/index.html. Source Zone Destination Zone Policy Action...
  • Page 3 Use the port labeled 0/0 (interface ge-0/0/0) to connect to your ISP. Your ISP will On the Configure System: Network Settings page of the Juniper Setup Wizard-SRX have provided a static IP address. You must configure the static IP address on the Series, enter the IP address of the device that connects your device with WAN services gateway as described in Task 6, Steps 1 through 4.
  • Page 4 Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice. Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S.