Using The Axlink Connector For Data And Power; Using The Axlink Four-Pin Connector And External 12 Vdc Power Supply - AMX Color Active-Matrix LCD Instruction Manual

Color active-matrix lcd mini-touch panel firmware version g3 or higher
Hide thumbs Also See for Color Active-Matrix LCD:
Table of Contents

Advertisement

Figure 22
Mini-XLR connector to exter-
nal 12 VDC power supply,
and Central Controller wiring
diagram
Figure 23
AXlink wiring diagram
Caution
If you are using power from
AXlink, disconnect the wiring
from the Central Controller
before wiring the touch panel.
20
Installing Mini-Touch Panels
4-pin mini-XLR
connector
2
1
3
4
4 - PWR (+)
3 - AXP
2 - AXM
1 - GND (-)

Using the AXlink connector for data and power

Connect the Central Controller's AXlink connector to the AXlink connector (male) on
the rear panel of the touch panel for data and 12 VDC power as shown in
23.
PWR (+)
AXP
AXM
GND (-)

Using the AXlink four-pin connector and external 12 VDC power supply

Connect the Central Controller's AXlink connector to the AXlink connector on the
rear panel of the touch panel as shown in Figure 24.
PWR (+)
AXP
Central Controller
AXM
GND (-)
UniMount or rack-mount
AXlink connector
Color Active-Matrix LCD Mini-Touch Panels
12 VDC power supply
PWR (+)
GND (-)
1
GND (-)
AXM
2
3
AXP
4
PWR (+)
Control system