Replacing A Versatile Interface Module (Vim) - Extreme Networks Summit X150 Series Hardware Installation Manual

Summit x150 series summit x250e series summit x350 series summit x450 series summit x450a series summit x450e series summit x480 series summit x650 series
Hide thumbs Also See for Summit X150 Series:
Table of Contents

Advertisement

Replacing a Versatile Interface Module (VIM)

The procedure for replacing a VIM is the same for both the VIM1 module in the Summit X650 series
switch and the VIM2 module in the Summit X480 series switch.
NOTE
VIM1 modules must be installed in Summit X650 series switches, and VIM2 modules must be installed in Summit
X480 switches. A VIM1 or VIM2 module will not operate if it is installed in the wrong switch series.
You need the following tools and materials to replace a VIM1 or VIM2 module:
ESD-preventive wrist strap
#2 Phillips screwdriver
CAUTION
Summit VIM1 and VIM2 modules are not hot-swappable. Disconnect power to the switch before removing an
installed VIM1 or VIM2 module. After a VIM1 or VIM2 module is installed in a compatible switch, you can hot-swap
SFP and SFP+ modules. Use only SFP and SFP+ modules approved by Extreme Networks.
To replace a VIM1 or VIM2 module:
1 Attach an ESD-preventive wrist strap to your wrist and connect the metal end to an appropriate
ground point on the rack.
2 Disconnect the switch power.
3 Remove the installed VIM
a Remove the retaining screws at the top corners of the module, and set the screws aside in a safe
place.
Save the retaining screws to secure the new module in the switch.
b Rotate the inserter/extractor levers downward to disconnect the internal module connectors.
c Carefully slide the module out of the switch and set it on an anti-static surface.
Figure 180: Removing a VIM (VIM1-SummitStack Module Shown)
4 Remove the replacement VIM from its anti-static packaging.
Summit Family Switches Hardware Installation Guide
(Figure
180):
SH_092
211

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents