Editor-Related Items
Level 3
ED-X
Use it to adjust the input coordinates in editor sub
scanning (X) direction.
ED-Y
Use it to adjust the input coordinates in editor main
(Note 1)
scanning (Y) direction.
LOOP-MB
Use it to adjust processing for reading images into
(Note 1)
memory when coloring in area select/color create
mode.
· A higher setting makes filling of gaps easier, but
too high a setting can lead to bleeding.
LOOP-TH
Use it to adjust the binary slice level for reading
(Note 1)
images into memory when coloring in area select/
color create mode.
· A higher setting enables reading fine lines.
MRK-MB
Use it to adjust processing for reading images into
memory in marker select/point select mode.
· A higher setting makes filling of gaps easier.
MRK-TH
Use it to adjust the binary slice level for reading
images into memory in marker select/point select
mode.
· A higher setting enable reading fine lines.
Note 1: Execute this mode upon replacement of a CPU PCB or initialization of the RAM. The settings
will be returned to standard settings, requiring you to enter the appropriate settings. Be sure to
record any new settings on the service label.
COPYRIGHT © 1999 CANON INC.
Description
ED-X
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 13 TROUBLESHOOTING
EDITOR>ADJUST
Remarks
-99 to +99
Unit: 0.13 mm (approx.)
Standard: 0
ED-Y
0 to 3
Standard: 0
0 to 255
Standard: 192
0 to 3
Standard: 0
0 to 255
Standard: 128
13-281