Controlling The Temperature Of The Photosensitive Drum; Control; Controlling The Power Using The Environment Switch Sw6 - Canon CLC 1120 Service Manual

Color laser copier
Hide thumbs Also See for CLC 1120:
Table of Contents

Advertisement

G. Controlling the Temperature of the Photosensitive Drum

1. Control

The photosensitive drum temperature control mechanism has the following items of control:
When the error temperature is reached, the control IC turns on to shut off the power to the drum
heater.

2. Controlling the Power Using the Environment Switch SW6

As long as the environment switch (SW6) is on, the drum heater remains powered regardless of
the state (on/off) of the main switch.
When the switch is off, on the other hand, the drum heater is powered only when the main
switch is on. At the time of shipment, the switch is set to OFF.
COPYRIGHT © 1999 CANON INC.
Item
Drum heater
Temperature measurement
Reference temperature
Error temperature
Table 6-301
SW6
Figure 6-307
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 IMAGE FORMATION SYSTEM
Description
60W
By thermistor (TH)
41°C
109°C
ON
OFF
6-25