<$chapnum
Country
Ecuador MFC-R2
Ecuador MFC-LME
Korea MFC-R2
392
AltiWare ACM 5.2 Administration Manual
Signaling Values
Set calling part category: 1
[Assume no caller ID provided]:
Incoming sequence: DID/DNIS
In-call signaling (depend on how many DID digits):
For 3-digit DID, set to (113)6
For 4-digit DID, set to (1113)6
For 5-digit DID, set to (11113)6
For 6-digit DID, set to (111113)6
For 7-digit DID, set to (1111113)6
For 8-digit DID, set to (11111113)6
[Assume caller ID provided]:
Incoming sequence (same as above shown):
DID/DNIS * Caller ID
In-call signaling (depend on how many DID digits):
For 3-digit DID, set to (115)*(K)36
For 4-digit DID, set to (1115)*(K)36
For 5-digit DID, set to (11115)*(K)36
For 6-digit DID, set to (111115)*(K)36
For 7-digit DID, set to (1111115)*(K)36
For 8-digit DID, set to (11111115)*(K)36
Set calling part category: 2
[The switch doesn't support caller ID transmission]:
Incoming sequence: DID/DNIS
In-call signaling (depend on how many DID digits):
For 3-digit DID, set to (113)1
For 4-digit DID, set to (1113)1
For 5-digit DID, set to (11113)1
For 6-digit DID, set to (111113)1
For 7-digit DID, set to (1111113)1
For 8-digit DID, set to (11111113)1
Set calling part category: 1
[The switch doesn't support caller ID transmission]:
Incoming sequence: DID/DNIS
In-call signaling (depend on how many DID digits):
For 3-digit DID, set to (113)6
For 4-digit DID, set to (1113)6
For 5-digit DID, set to (11113)6
For 6-digit DID, set to (111113)6
For 7-digit DID, set to (1111113)6
For 8-digit DID, set to (11111113)6