Starting, stopping, and rebooting the system
Powering on the controller
Operator Guide
3.
Managing the system
This chapter provides management-related information that
pertains to the system as a whole such as starting, stopping, and
rebooting the system and operating the tape drives.
Shut down and reboot the system only when you are directed in
the "Troubleshooting" chapter of this guide; or after loading new
software, such as Novell NetWare or AppleTalk gateways.
Do not use either of the following methods to shut down the
controller:
•
The Quit option on the pull-down menu of any window
•
The Exit option on the Workspace pop-up menu
Wait at least one minute after power has been switched off
before continuing. Then switch on power to the controller
components in the following order:
1. Any external SCSI devices, starting with the unit with the
SCSI terminator and following the connection chain toward
the Sun workstation
2. Other peripherals
3. Monitor
4. Sun workstation
When the operating system finishes rebooting, the Xerox
application software starts. When the DocuSP Print Services
window displays, power on the printer.
CAUTION
3-1