Debug Console Window

3-9-5 [Replay] Menu

[IO Condition]
84
This section explains how to operate the sub-menu of the [Replay] menu.
Start the IO Condition tool to display the [Run] window (the startup window for
this tool).
Note Refer to 8 Debugging Using Virtual External Inputs for the details of the I/O
Condition tool.
IO condition file
Target FINS Ad-
dress
Synchronized
Start/Stop button
Status Display
Input the name of the execution file for I/O Condition.
Browsing files with the Browse button is also possible.
Input the destination FINS address for monitoring I/O
Condition. The FINS address for the Ladder Engine is
displayed as the initial value. Changing it during the
execution is not possible.
Specify whether or not to perform the synchronous
process. When in the process, the conditional moni-
toring will be performed to the Ladder Engine in the unit
of a single scan. When in the asynchronous, at a fixed
interval.
Pressing the Start button will monitor I/O Condition.
The button works as Stop button during execution.
When starting, the message box is displayed at the
destination. The process will be started after confirma-
tion.
Display the process status on the Status bar.
Section 3-9