Omron WS02-SIMC1-E - V1.9 REV 12-2009 Operation Manual page 102

Table of Contents

Advertisement

System Status Setting Window
Outline/Detail Status Display Change
Outline display mode
Displayed Items in the Detail Status Display.
Pressing the Outline/Detail Status Display button switches the [System Status
Setting] window display between Outline and Detail.
Name
Time
Current PLC
infor-
Time
ma-
tion
Cycle time
counter
Cycle
Virtual Cycle
time
Time (Virtual
infor-
time)
ma-
Virtual Ladder
tion
Diagram Exe-
cution Time
Virtual Time for
Peripheral Ser-
vicing
Computer Cy-
cle Time (Com-
puter time)
Command Log Settings Yes/No of Command log settings presence
I/O Break Condition
Settings
Detail display mode
Function
Display current PLC time. The time may be different
from that of the computer as they are independent
each other.
Display the cycle time counter.
Display the values of present, minimum, maximum,
and average (recent 8 times) virtual cycle times.
(unit: ms)
Display the present value of the virtual execution
time only for UM1 program. (unit: ms)
Display the virtual value of peripheral servicing time
including overseeing and I/O refreshing. (unit: ms)
Display the present, minimum, maximum, and av-
erage (recent 8 times) values of computer cycle
times
Yes/No of I/O break condition settings presence
Section 3-7
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac ws02-simc1-eCx-simulator 1.9

Table of Contents