Comparison of the CX-Simulator and SYSMAC CS/CJ-series PLCs
Item
Instructions
Sequence Input
Sequence Output
Sequence Control
Timer/Counter
Comparison
Data Movement
Data Shift
Increment/Decrement
Symbol Math
Conversion
Logic
Special Math
Floating-point Math
Table Data Processing
Tracking
Data Control
Subroutines
Interrupt Control
Step
Basic I/O Unit
Serial Communications
Network
File Memory
Display
High-Speed Counter Pulse
Control Instructions (CJ1M
only)
Clock
Debugging
CS/CJ-series PLC
Equivalent
Equivalent
Equivalent
Equivalent (TRSET is equivalent only for CJ2-series PLCs.)
Equivalent
Equivalent
Equivalent
Equivalent
Equivalent
Equivalent (GRAY_BIN, GRAY_BINL, BIN_GRAY, BIN_GRAYL are
equivalent only for CJ2-series PLCs.)
Equivalent
Equivalent
Equivalent (A rounding error may occur.)
Equivalent
MAXL, MINL, MAXF, MINF, MAXD, MIND are equivalent only for
CJ2-series PLCs.
Equivalent (Nothing is executed for PID.)
Equivalent
Equivalent
Equivalent
IORF, IORD, IOWR, TKY, HKY,
7SEG, and DSW available.
PMCR, and PMCR2 available.
TXD, RXD, and STUP available.
SEND, RECV, and CMND available.
CSND available.
Equivalent
Equivalent (Messages of Programming Console are displayed on the
screen.)
INI, SPED, PRV, PRV2, CTBL,
PULS, ACC, PLS2, ORG, and PWM
instructions
Equivalent (With the CX-Simulator, however, even if the time in the PLC is
adjusted with the DATE instruction, it will be automatically corrected to the
time in the computer at the end of the cycle in which the DATE instruction is
executed.)
Equivalent
Section 1-6
CX-Simulator
Equivalent (The MILH and MILR
instructions, however, cannot be
used to control the ON/OFF status
of interlocks by forcing ON/OFF
the bit specified for the second
operand. The interlocks must be
controlled through the execution
condition of the instruction.)
Nothing is executed for the IORF,
IORD, or IOWR instructions.
Nothing is executed for PMCR or
PMCR2.
TXD, RXD, and STUP operate
differently depending on commu-
nications parameters.
TXDU2, and RXDU2 operate only
for CJ2-series PLCs.
SEND, RECV, and CMND operate
differently depending on commu-
nications parameters.
Nothing is executed for CSND.
SEND2, RECV2, and CMND2
operate only for CJ2-series PLCs.
Nothing is executed for the in-
structions listed at the left.
21