How to Use Data Trace Recording Tool
Item
Trace status
Display the Trace Status while tracing data.
Elapsed
The time elapsed after execution started in the unit of
hour/minute/second (e.g. 1 hour 10 minutes 30 seconds).
Trace number
Number of traced samples.
of samples
Saving file
Current file name when Multiple Saving is set.
Read settings
Read settings from the existing ini file to display it in the window.
button
Save settings
Save the settings to the ini file.
button
Option button
Set options regarding the trace data recording.
Start button
Change the caption between [Start] when not tracing and [Stop]
Stop button
when tracing.
Press the [Start] button to start tracing and the [Stop] to stop.
Exit button
Exit the Data Trace Recording Tool.
Exit the tool after the PLC completes tracing if the PLC is exe-
cuting tracing.
Option Settings
Add Recording
Divide
Recording
Add Recording
Divide Recording
Divide Recording not
used
Divide Recording
OK button
Cancel button
254
Description
If the file specified by the Trace Data Record File exists, the data will be ap-
pended to the file.
Specify whether the sampling data is to be saved to one file or multiple files.
Save the sampling data to one file, where the tracing ends automatically when
acquired 32,767 samples.
Divide and save the sampling data to multiple files. Change automatically to
the next file when acquired 32,767 samples.
Serial numbers will be attached to the end (excluding an extension) of the
specified file name.
Register the option settings to close the dialog box.
Close the dialog box without registering option settings.
Appendix
Limit of values
OK button
Cancel button