Areas for Control/Notification
Controlling the NT11 Status by Using Allocated Bits and Words ..... PT Status Control Area (PLC to PT)
Words Allocated for the PT Status Control Area
Symbol
C-series PLCs
None
IR Area
H
HR Area
A
AR Area
L
LR Area
T
TC Area,
Timer PVs
TU
---
C
TC Area,
Counter PVs
CU
---
W
---
TK
---
D
DM Area
The PT status control area (PLC to PT) is provided to control the NT11 status
from the PLC. When data is written to this area in the PLC, the NT11 will read
the data and operates according to the data. The PT status control area is
configured as four consecutive words as shown below.
Word 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
n
0
n+1
Copy type
n+2
n+3
The first word (word n) of the PT status control area must be set with the sup-
port tool.
• Screen switch settings (refer to page 110)
Specify the screen No. to switch the screen displayed on the NT11.
• Copy memory table settings (refer to page 121)
Specify the memory table entry No. to copy the contents of a memory table
entry internally in the NT11.
Set the copy type to match the type of memory table entry to be copied:
0: Character-string memory table
1: Numeral memory table
• PT status control bits (refer to page 129)
Set the bits ON or OFF according to the following table to control the back-
lighting. For the bit configuration, refer to 5-5-1 Controllable NT11 Func-
tions (page 129).
The PT status control area (PLC to PT) can be allocated to the following
PLC areas.
Words can be allocated for the PT status control area (host « PT) in the fol-
lowing host (PLC) areas.
Allocation
CV-series PLCs
OK
CIO Area
OK
---
OK
Auxiliary Area
OK
---
No
Timer Area,
Timer PVs
---
---
No
Counter Area,
Counter PVs
---
---
---
---
---
---
OK
DM Area
Screen No. (4-digit BCD)
Copy source memory table entry No. (3-digit BCD)
Copy destination memory table entry No. (3-digit BCD)
PT status control bit
Allocation
CS/CJ-series PLCs
OK
CIO Area
---
HR Area
No
AR Area
---
*1
LR Area
No
TC Area,
Timer PVs
---
TC area,
Timer Completion Flags
No
TC Area,
Counter PVs
---
TC Area,
Counter Completion Flags
---
WR Area
---
Task Flags
OK
DM Area
Section 4-3
Screen switch
setting
Copy memory
table settings
PT status control
Allocation
OK
Not for Host
Link
OK
Not for Host
Link
No
No
No
No
Not for Host
Link
No
OK