Frequency-Domain Results

66
Find Quality Products Online at:
The test limit and cable type used for the test. To see all the
settings used for the test, tap the panel.
To see detailed results for a test, tap the panel.
The overall result for the Autotest. If the result shows an
asterisk, See "PASS*/FAIL* Results" on page 61.
The overall result for the test:
The results exceed the limit.
The results are within the limit.
The selected test limit does not have a limit for the test, or
a dB rule applies. See the Technical Reference Handbook.
The results are within the range of accuracy uncertainty
for the tester. See "PASS*/FAIL* Results" on page 61.
The measurement shown for frequency-domain results is the
worst margin. (The insertion loss plot is different. See the
Technical Reference Handbook.)
When more than one button shows at the bottom of the
screen, the tester highlights one in yellow to recommend
which one to tap. See "Buttons to Do Tests and Save Results"
on page 22.
Frequency-domain results are the measurements that change
with frequency, such as insertion loss and crosstalk.

How to Save Frequency-Domain Results as a Plot or a Table

If Store Plot Data is on when you do a test, the saved results show
as plots. If Store Plot Data is Off, the tester does not save plot data
for frequency-domain tests or for the HDTDR/HDTDX analyzers.