The Safety Temperature Limiter Has Tripped. Operation Not Possible (1480) - Henny Penny FSHN610 Service Instructions Manual

Table of Contents

Advertisement

Fault messages & troubleshooting

The safety temperature limiter has tripped. Operation not possible (1480)

64
Description
There is a response from the safety circuit on the control board.
A1
STEUERPLATINE
CONTROL PCB
F500
3,15AT
K1
1 2
X20
X19
X21
-B0
-Q1
-B11
Hauptschütz
Main Contactor
Image: Overview of the safety circuit
A1 Control board
B1
Safety temperature limiter
1
Service-instructions
1
Thermal switch
70°C (158 °F)
2
1
STB Garraum
STL Cabinet
2
B0 Thermal switch
Q1 Main contactor