6.4 CombiDoctor

Description
CombiDoctorStart
Selecting a program
Starting the program
Evaluation
Description of the test steps
The CombiDoctor offers an automatic check of the climate control
system and WaveClean automatic cleaning. The tests are possible
individually or as overall test. For instructions on performing, see the
touchscreen.
Image: Select CombiDoctor test
Select a program by adjusting the roller.
Touch the "START" field.
The test result appears on the touchscreen.
Entry in HACCP memory.
Step 1 (test door contact)
1. Open cooking chamber door and close again.
If test successful, proceed with the next test step.
If the door is not recognized as having been opened and
closed again within the specified time (60 seconds), the test is
not passed.
Step 2 (prepare for WaveClean)
1. Preparation for WaveClean test.
Automatic water exchange via the siphon pump and the solenoid
valve for steam elimination.