4.2 Removing and attaching the unit cover

4.2.1 Removing the unit cover on a tabletop unit

4.2.2 Attaching the unit cover on a tabletop unit

NOTICE
b
a
Image: Removing the unit cover
a Unit cover
b Steam outlet nozzle
CE
Seal
sym
bol
1. Unscrew the lid from the air inlet nozzle.
2. Remove the ventilator ring.
3. Unscrew the screws on the unit cover.
4. Carefully remove the unit cover.
Risk of property damage from leaky housing
• Check seals when attaching the housing parts.
• Replace damaged seals.
1. Brush the seal on the steam outlet nozzle with an acid-free slip
agent.
2. Carefully push the unit cover over the steam outlet nozzle and air
inlet nozzle.
The air inlet nizzle must be pushed through the cut-outs on the
unit cover.
3. Press the unit cover onto the housing.
4. Screw in the screws on the unit cover.
The unit cover must be in contact with the unit on all sides.
5. Put the ventilator ring on with the cut-outs facing upwards and
ensure that it can not be rotated.
6. Screw the lid onto the air inlet nozzle.