6.8 DynaSteam test

Description
Prerequisite Access to the water supply pipe in the cooking chamber.
Starting the test
Check the water quantity
The DynaSteam test allows a function test of DynaSteam steaming.
Calibration is not possible / necessary.
Remove both hook-in points.
Dismount water supply pipe.
Dismount air diverter.
Replace water supply pipe.
Image: Overview of DynaSteam test
Touch "Initialization" field.
Automatic pre-rinse.
Field changes to "START".
Set water quantity using the rollers.
Touch the "START" field.
Energize solenoid valve for steaming.
The water comes runs from the water supply pipe into the
cooking chamber.
Collect the water from the supply pipe with a measuring container.
Starting water test.
After the predetermined amount of water has gone through,
activation stops automatically.
Compare amount of water with the set value. A deviation of +-
10% is within tolerance.