SmartCombi™ & ClassicCombi™ Service

Core temperature probe replacement instructions

Valid for:
SmartCombi ClassicCombi MM203697 MM203688
Arrangements:
Disconnect unit from the power supply
Unit version 615, 620, 115, 120, 215 & 220 Electric:Unlock and open front panel.
Only at unit version 215 & 220 Gas: Unlock and open front panel and remove the left side wall.
At the floor version 215 & 220 the protection cover for the electronic must be removed in addition.
Disconnect core temperature probe from
terminal X12 respectively from X16. Using a
"precision" (small) flat head screwdriver
remove each wire from the connector by
pressing on the spring loaded lock on top of
each wire.
B1 = Core temperature probe
Remove cord grip
Remove core temperature probe.
The probe is located at the front upper
cabinet corner.
Mount new probe in reversed order.
X16
B1
Assignment SmartCombi
Unit version 6xx / 1xx
Unit version 2xx
No.09 HD_04/2008
X12
B1
Assignment ClassicCombi
1