SmartCombi™ & ClassicCombi™ Service
Core temperature probe replacement instructions
Valid for:
SmartCombi ClassicCombi MM203697 MM203688
Arrangements:
Disconnect unit from the power supply
Unit version 615, 620, 115, 120, 215 & 220 Electric:Unlock and open front panel.
Only at unit version 215 & 220 Gas: Unlock and open front panel and remove the left side wall.
At the floor version 215 & 220 the protection cover for the electronic must be removed in addition.
Disconnect core temperature probe from
➢
terminal X12 respectively from X16. Using a
"precision" (small) flat head screwdriver
remove each wire from the connector by
pressing on the spring loaded lock on top of
each wire.
B1 = Core temperature probe
Remove cord grip
➢
Remove core temperature probe.
➢
The probe is located at the front upper
cabinet corner.
Mount new probe in reversed order.
➢
X16
B1
Assignment SmartCombi
Unit version 6xx / 1xx
Unit version 2xx
No.09 HD_04/2008
X12
B1
Assignment ClassicCombi
1