Henny Penny FSHN610 Service Instructions Manual page 35

Table of Contents

Advertisement

Selecting parameters
Changing parameters
Parameter overview
No.
Basic setting
7
User menu password
16
Cooking chamber temperature
offset
21
Core temperature offset,
sensor 1
22
Core temperature offset,
sensor 2
23
Core temperature offset,
sensor 3
24
Core temperature offset,
sensor 4
42
Activation of the power
optimization system
45
Generator mode
48
Steam elimination mode
49
Controls the cooking chamber
lamp when opening the
cooking chamber door
Selecting parameters by adjusting the caster.
Tap the "Read" button.
Display of set parameters.
Use the number block to set the desired value.
Tap the "Write" button.
Changes saved.
Standard
Adjustment
worth
range
111
0 - 300
-9.9 - +9.9°K
-9.9 - +9.9°K
-9.9 - +9.9°K
-9.9 - +9.9°K
-9.9 - +9.9°K
0
0 = Off
1= On
0
0 = Off
1 = On
1
0 = Low
1 = Normal
2 = High
0
0-60 seconds
Service-instructions
Service menu - appliance test
Explanation
Password for the user menu (basic settings)
Ability to retrieve the saved temperature offset
values. The can also be changed and saved.
The calibration function in the Service menu is
used for calibration!
Activate the ability to connect a power
optimization system. Optional equipment
feature. Activate additional parameter 110.
Only when using generators on ships.
"Low" setting: Minimum water consumption,
but higher condensate temperature and
greater steam volume. "High" setting:
Maximum water consumption, but lower
condensate temperature and smaller steam
volume.