Emergency Operation - Henny Penny FSHN610 Service Instructions Manual

Table of Contents

Advertisement

11.2 Emergency operation

Description In order to allows limited use in case of error, the appliance has
INFORMATION
Overview
Cooking sensor defective.
Water vapor sensor defective
Core temperature sensor defective. Cooking program was
canceled.
various emergency programs. Emergency operation is activated
automatically and displayed. After elimination of the error indicated,
the controller switches back into regular operation automatically. A
reset is not necessary.
Emergency programs handle the limited further operation of the appliance until
servicing. Deviating cooking results and temperature deviations are possible.
Fault message displayed
Service-instructions
Fault messages & troubleshooting
Description
The core temperature sensor takes over the
function of the cooking chamber sensor.
The software controls the water vapor
elimination. This results in higher water
consumption.
Function no longer available.