Faulty Can Connection; 5007: Not Enough Storage Space For Software Update; 5008: No New Version Found - Henny Penny FSHN610 Service Instructions Manual

Table of Contents

Advertisement

Fault messages & troubleshooting

Faulty CAN connection

5007: Not enough storage space for software update

5008: No new version found

72
Description
There is a communication fault between the operating panel and
control panel. In addition, temperature sensor and fan fault messages
appear on the touchscreen.
Troubleshooting
Replace communication cable between operating panel and
control panel circuit board.
Replace control board.
Replace operating panel.
Description
The internal memory is full. The current version will be restarted. The
cause can be faulty data import (additional content).
Troubleshooting
Replace operating panel. Alternatively, continue to operate with
the current software.
Send the operating pane to the manufacturer for repair.
Description
The following causes generate the message:
USB stick not recognized or not present
Required content not present on the USB stick or saved incorrectly.
The software version on the unit is newer than that on the USB stick.
Troubleshooting
Check content and structure of the USB stick.
Ensure that the USB interface is functioning properly.
On USB sticks with an LED, the LED must be on.
Check communication, e.g. by exporting HACCP data
Use a different USB stick
If the message appears after a software update, confirm by pressing
"OK". In individual cases, this may be required several times.