Fault in moisture removal control. Limited operation
Is at least one LED strip in the cooking chamber door on when the unit is switched
Check the e-fuse on the control board and reset if
necessary.
Is at least one LED strip in the cooking chamber door
on when the unit is switched on?
Call up the relay test in the service menu. Energize
lift magnet (K8). Is the lift magnet energized?
Call up the relay test in the service menu. Switch on
solenoid valve humidification (K9). Is the solenoid
valve energized?
Measure the voltage at the solenoid valve.
24 V DC present = solenoid valve defective
24 V DC not present = control board defective
Description
The control board monitors, among other things, the power
consumption of the lift magnet. In the event of a fault, the fault
message appears and the e-fuse may trip.
Troubleshooting
No
Yes
No
Yes
No
Yes
No
Service-instructions
Fault messages & troubleshooting
on?
Control board defective.
Measure the voltage at the lift magnet.
24 V DC present = lift magnet defective
24 V DC not present = control board defective
75