Reset The Safety Controller To Factory Defaults; Factory Defaults - Banner SCR P Series Instruction Manual

Safety controller
Table of Contents

Advertisement

Programmable Safety Controller SCR P
If the configuration or the passwords on the Safety Controller and the SCR P-FPS do not match, the USB
LED flashes red. If the SCR P-FPS is not disconnected from the Safety Controller within 3 seconds, the
power/fault and USB LEDs flash red and the Safety Controller enters a lockout state due to the mismatch.
7. Cycle the power.
The power/fault LED is green, the USB LED is green (if the SCR P-FPS is still plugged in) or red (no SCR P-FPS
or USB cable connected), and the Input and Ouput LEDs show actual input status.
The Safety Controller is ready for commissioning. See

11.8 Reset the Safety Controller to Factory Defaults

The Safety Controller must be powered up and connected to the PC via the USB cable.
1. Click
.
2. Click Reset to Factory Default.
A caution displays reminding you that all settings will change to factory defaults.
3. Click Continue.
The Enter Password screen opens.
4. Enter the User1 password and click OK.
The Safety Controller is updated to the factory default settings and a confirmation window displays.
5. Click OK.
6. Cycle the power.
The reset to factory default process is complete.

11.9 Factory Defaults

The following table lists some of the factory default settings for both the Safety Controller and the Software.
Setting
AVM Function
Closed-to-Open Debounce Time
EDM
Function Block: Bypass Block Default Nodes
Function Block: Bypass Time Limit
Function Block: Delay Block—Default Nodes
Function Block: Delay Block—Output Delay
Function Block: Enabling Device Block—Default Nodes
Function Block: Enabling Device Block—Time Limit
Function Block: Latch Reset Block—Default Nodes
Function Block: Muting Block—Default Nodes
Function Block: Muting Block—Time Limit
Function Block: Two-Hand Control Block—Default Nodes
Industrical Ethernet: String (EtherNet/IP and PCCC Protocol) 32 bit
Network Settings: Gateway Address
Network Settings: IP Address
Network Settings: Link Speed and Duplex Mode
182
Commissioning Checkout Procedure
Factory Default
50 ms
6 ms
No monitoring
IN, BP
1 s
IN
100 ms
ED, IN, RST
1 s
IN, LR
IN, MP1
30 s
TC
0.0.0.0
192.168.0.128
Auto Negotiate
www.bernstein.eu
- Tel: + 49 571 793 0
on p. 165.
Applicable Product
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P
SCR P