9 Industrial Ethernet Overview

9.1 Configuring the Safety Controller

Make sure that Enable Network Interface is selected, and the network settings are configured as needed by the chosen
protocol.
1. Connect the Safety Controller to your PC via the USB cable to enable the port.
2. Open the BERNSTEIN Safety Controller Software.
3. Click
Network Settings.
4. Select the Enable Network Interface checkbox.
5. Configure the IP Address and Subnet Mask as needed for your network.
Note: If a Virtual Reset or Cancel Delay is used, an Actuation Code must be defined and then sent
to the Safety Controller.
6. Click Send.
7. Click on the Advanced arrow to configure the Advanced network settings, if desired.
The following are the default values for the Safety Controller's Ethernet port and Industrial Ethernet options.
8. Provide the appropriate password to change the configuration and network settings for the Safety Controller.
9. Make sure the Safety Controller has a valid and confirmed configuration file.
The Ethernet port is enabled.
Figure 99: Default Values
www.bernstein.eu
- Tel: + 49 571 793 0
Programmable Safety Controller SCR P