Programmable Safety Controller SCR P
Fault Code
Fault Code Description
3.2
EDMxx Fault
3.3
EDMxx Fault
3.4
EDMxx Fault
3.5
EDMxx Fault
3.6
EDMxx Fault
3.7
EDMxx Fault
3.8
AVMxx Fault
3.9
Input Fault
3.10
Internal Fault
4.1
Supply Voltage Low
4.2
Internal Fault
4.3 – 4.12
Internal Fault
4.13
Configuration Timeout
4.14
Configuration Unconfirmed
4.15 – 4.19
Internal Fault
4.20
Unassigned Terminal in Use
4.21 – 4.34
Internal Fault
4.35
Overtemperature
4.36 – 4.47
Internal Fault
4.48
Unused output
4.49 – 4.59
Internal Fault
4.60
Output Fault
5.1 – 5.3
Internal Fault
6.xx
Internal Fault
10.xx
Internal Fault
190
EDM contact(s) failed to close within 250 ms after the Safety Outputs turned Off:
Check for a slow or stuck On contactor or relay
Check for an open wire
EDM contact(s) opened prior to turning On the Safety Outputs:
Check for a stuck On contactor or relay
Check for an open wire
EDM contact pair mismatched for longer than 250 ms:
Check for a slow or stuck On contactor or relay
Check for an open wire
Check for an unstable signal on the input
Check for a short to ground
Check for a short between inputs
After this Safety Output turned Off, an AVM input associated with this output did not close before
its AVM monitoring time expired:
The AVM may be disconnected or its response to the Safety Output turning Off may
be too slow
Check the AVM input and then perform a System Reset to clear the fault
The AVM input was open, but should have been closed, when the associated Safety Output was
commanded On:
The AVM may be disconnected. Check the wiring to the AVM
Internal failure— Contact BERNSTEIN AG (see
The supply voltage dropped below the rated voltage for longer than 6 ms:
Check the power supply voltage and current rating
Check for an overload on the outputs that might cause the power supply to limit
the current
A configuration parameter has become corrupt. To fix the configuration:
Replace the configuration by using a backup copy of the configuration
Recreate the configuration using the Software and write it to the Safety Controller
Internal failure— Contact BERNSTEIN AG (see
The Safety Controller was left in Configuration mode for more than one hour without receiving
any commands from the Software.
The configuration was not confirmed after being edited:
Confirm configuration using the Software
Internal failure— Contact BERNSTEIN AG (see
This terminal is not mapped to any device in the present configuration and should not be active:
Check the wiring
Internal failure— Contact BERNSTEIN AG (see
An internal overtemperature condition has occurred. Verify that the ambient and output loading
conditions meet the specifications of the Safety Controller.
Internal failure— Contact BERNSTEIN AG (see
A voltage was detected on an unconfirmed terminal.
Internal failure— Contact BERNSTEIN AG (see
An output terminal detected a short. Check output fault for details.
Internal failure— Contact BERNSTEIN AG (see
Invalid configuration data. Possible internal failure:
Try writing a new configuration to the Safety Controller
Internal failure— Contact BERNSTEIN AG (see
www.bernstein.eu
- Tel: + 49 571 793 0
Steps to resolve
Repairs and Warranty Service
Repairs and Warranty Service
Repairs and Warranty Service
Repairs and Warranty Service
Repairs and Warranty Service
Repairs and Warranty Service
Repairs and Warranty Service
Repairs and Warranty Service
on p. 191)