4. Replacement and Adjustment
9.
Remove the two screws fixing the auto-nozzle check bracket (
10.
Turn the auto-nozzle check unit [B] forward while releasing the hook [A] of the auto-
nozzle check bracket, and pull it out from the opening of the right back of the main unit.

After Replacement

After changing the auto-nozzle check upper unit or auto-nozzle check unit, perform the procedures
below.
1.
Perform SP2-024-004 to reset the counters.
The counters shown below will be reset.
SP7-761-011 to 019
SP7-767-011 to 020
SP7-768-011 to 020
SP7-761-020
SP2-021-011
542
SP
Auto-nozzle checking time
Accumulated value of no-purging
Accumulated value of no-purging lines
Electrode-plate wiping time
Flag for operating life of the auto-nozzle check
x2).