Carriage Unit
Attach the main ink level sensor bracket in the procedure below.
1. Loosen the screw of the bracket to move the bracket back and forth.
2. Check that the feeler is placed at the center of the feeler sensor [1] [2]. If it is not placed at the
center, adjust the position by moving the bracket back and forth.
3. Tighten the screw of the bracket.