Data Overwrite Security Unit Type M19

Overview

This option should be installed only for the customer who requires the CC certified Data Overwrite
Security function.
The function of this option is completely the same as the Data Overwrite Security in Security Functions,
which is standard on this machine.

Before You Begin the Procedure

1. Confirm that the Data Overwrite Security unit SD card is the correct type for the machine. The
correct type for this machine is "Type M19".
• If you install any version other than "Type M19", you have to replace the NVRAM and do this
installation procedure again.
2. Make sure that the following settings are not at their factory default values:
• Supervisor login password
• Administrator login name
• Administrator login password
If any of these settings is at a factory default value, tell the customer these settings must be changed
before you do the installation procedure.
3. Make sure that "Admin. Authentication" is ON.
[System Settings] – [Administrator Tools] – [Administrator Authentication Management] - [Admin.
Authentication]
If this setting is OFF, tell the customer this setting must be ON before you do the installation
procedure.
4. Make sure that "Administrator Tools" is enabled (selected).
[System Settings] – [Administrator Tools] – [Administrator Authentication Management] - [Available
Settings]
If this setting is disabled (not selected), tell the customer this setting must be enabled (selected)
before you do the installation procedure.
Controller Options
165