Ricoh MP CW2201 Field Service Manual page 464

Hide thumbs Also See for MP CW2201:
Table of Contents

Advertisement

4. Replacement and Adjustment
9.
Connect the FFCs (front side) to the upper connectors at the lower part of the HRB. (
x3)
• If the FFC is pulled after connecting to the HRB, it may be hooked into the OCFS actuator.
Then the FFC becomes longer than the required length to the connector and the deflected part
may push the OCFS actuator. In this case, release the FFC and release the hooked part. Then
connect it to the HRB again.
458
Not hooked
1: Filler
2: FFC
3: HRB
Hooked

Advertisement

Table of Contents
loading