9
|
Electrical installation
Installer reference guide
90
b An excessive strip length may cause electrical shock or leakage
3 Insert the wiring at the back of the unit:
c
b
a
a Power supply cable (high voltage)
b Communication cable (high voltage)
c Cable for bottom plate heater (optional)
4 Inside the unit, route the wiring as follows:
b
a
e
f
a Power supply cable
b Communication cable
c Cable for bottom plate heater (optional)
d Ferrite core
e Tie strap
f Compressor
NOTICE
To guarantee electromagnetic compatibility:
▪
Make sure both power supply and communication cables run parallel to one
another. Use tie straps to hold the cables together.
▪
Make sure the cables are located as far away from the compressor as possible.
▪
The communication cable MUST pass through the ferrite core.
5 Make sure that the cable does NOT come in contact with sharp edges or hot
gas piping.
6 Install the switch box cover.
d
e
EPGA11~16DAV3(7) + EAVH/X16S18+23DA6V(7)+9W(7)
c
e
e
e
Daikin Altherma 3 H F
4P556070-1A – 2021.09