Download Print this page

Electrical Safety Check; Operation Check - Stiga PARK PRO 540 IX Workshop Manual

2016-2021
Hide thumbs Also See for PARK PRO 540 IX:

Advertisement

PARK PRO 540 IX - 740 IOX

7.4 Electrical safety check

Machine start is consented by the safety system if the following conditions are met.
Parking brake engaged.
Operator seated.
• Turn the ignition key to the ON position.
• Press START key.
• If all the aforementioned conditions are met, the engine starts.
In the following table you will find the interventions of the safety devices in
the various situations of use.
A) Start-up
Driver
Absent
Seated
Seated
B) During mowing
Driver
It lifts up.
It lifts up.
It lifts up.
It lifts up.

7.4.1 Operation check

Set-up for the check:
Disconnect the connectors CN1, CN2 and CN3 of the wiring from the electronic card - To
identify the connectors.
Set the tester to the requested operating mode "ohmmeter" or "voltmeter"
Make contact with the probes on the contacts of the wiring connector as described be-
low.
WORKSHOP MANUAL
Parking brake
Engaged
Deactivated
Engaged
Parking brake
Engaged
Deactivated
Deactivated
Engaged
Chapter
7 - Electrical System
Engine
Cutting means
Off
Deactivated
Off
Deactivated
Off
Deactivated
Engine
Cutting means
On
Deactivated
On
Deactivated
On
Engaged
On
Engaged
EDITION
Page
2018
9
Result
It does not start.
It does not start.
It starts
Result
It stays on
It switches off
It switches off
It switches off

Hide quick links: