Ntak03 Tds/Dtr Card - Nortel Meridian 1 Succession 1000M Installation And Configuration Manual

Small system
Hide thumbs Also See for Meridian 1 Succession 1000M:
Table of Contents

Advertisement

Table 23
Jumper settings
Port
Port 0
Port 1
Port 2
Port 3
2
Insert the card in its assigned slot.
You can install the NTAK02 SDI/DCH card in:
slots 1 through 10 of the cabinet
slots 1 to 3 of the chassis
3
Connect an NTAK19FB four port cable (or an NE-A25B cable) from the
corresponding connector at the back of the chassis. If you use an
NE-A25B cable, terminate this cable at the cross-connect terminal.
Because the NTAK19FB cable is equipped with connectors, it does not
require termination at the cross-connect terminal.

NTAK03 TDS/DTR card

The NTDK20 SSC card provides the NTAK03 TDS/DTR card functionality.
However, the TDS/DTR card can coexist with the SSC card if you wish to
access extra TDS/DTR units or SDI ports. These functions must be manually
programmed in the software overlays.
Note: The system may not operate properly if an NTAK03 circuit card
is installed in a slot connected to telephones. Refer to "Installing and
connecting cross-connect terminals" on
NTAK03 circuit card to the cross-connect terminal.
Installing optional circuit cards
Strap
Jumper
for
location
DTE
J10
C - B
J7
C - B
J6
C - B
J5
C - B
J4
C - B
J3
C - B
End of Procedure
Small System
Strap
for
Jumper
DCE
location
B - A
B - A
J9
B - A
J8
B - A
B - A
J2
B - A
J1
page
235, to connect an
Installation and Configuration
Page 221 of 562
RS422
RS232
C - B
B - A
C - B
B - A
C - B
B - A
C - B
B - A

Advertisement

Table of Contents
loading

Table of Contents