26

Gas Line Location

NOTE FOR RIGID PIPE: When using rigid pipe, you may wish to disconnect the shutoff valve from the fireplace
and route the pipe through the fireplace wall. First, disconnect the gas line from the shutoff valve. Disconnect
the shutoff valve from the cover plate (4 screws outside fireplace). The pipe may be routed through the cover
plate and the shutoff valve and gas line may be re-attached inside the fireplace.
Gas line may be plumbed from the left side (stock) or below. See illustration and table below to determine gas line location.
Left Side Gas Pass-Through Location (Stock)
Baseplate Gas Pass-Through Location*
a
b

Relocating the Gas Line to the Baseplate

1.
Remove the knock-out in the desired location (you may wish to remove both knockouts if routing electrical through
the base as well).
2.
Route the flex gas line (with shutoff valve) to the desired location.
© Travis Industries
Installation
(for qualified installers only)
42 PB - a
6-1/4" (159mm)
11" (280mm)
42 PB - b
2-1/2" (64mm)
21-1/4" (540mm)
4/19/23 - 1453
54 PB - a
6-1/4" (159mm)
2-1/2" (64mm)
10" (254mm)
31-1/8" (791mm)
b
a
PB 42 & 54 MV/GSB2/GSR2 Install
54 PB - b