CoolSmart TV – Overview (Optional)
The CoolSmart system is designed to redirect the convective heat of the fireplaces from the front of the unit, just
above the glass, to a location higher on the wall. The use of this kit allows for reduced clearances to televisions
and a recessed cavity above the fireplace. When using this kit, disregard the standard framing dimensions and
follow the framing instructions for the CoolSmart kit.
When used on the PB 42 & 54, this kit allows for the non-combustible facing height to be reduced. See
illustration below for details.
Ceiling
Min. 1-1/2" (39mm)
Max. 120"
(3048mm)
Min. 66-1/2"
(1690mm)
Min. 39"
991mm
© Travis Industries
Installation
Min. 1-1/4"
(32mm)
Television
Min.
10-3/8"
264mm
Min. 36"
915mm
28-5/8"
728mm
(for qualified installers only)
Max. 4-1/4" (108mm)
Optional Recessed Pocket
(Min. 39" 991mm above base of fireplace,
13-3/8" 340mm above top of screen trim)
Combustible Facing
(Min. 28-5/8" 728mm
above base of fireplace)
Non-Combustible
Facing Only
Top of Screen Trim
ProBuilder
(25-5/8" 651mm above
base of fireplace)
Linear
Fireplace
4/19/23 - 1453
PB 42 & 54 MV/GSB2/GSR2 Install