Vent Configuration: Vertical Termination for 42 PB ONLY
Use 4x6-5/8" Diameter Coaxial Vent. Connect a 8" to 6-5/8" reducer directly to the fireplace (sku
98900165).
NOTE: The included thimble assembly is not required and may be discarded.
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.
Up to four elbows (30°, 45°, 60° or 90°) may be used. Only one horizontal elbow may be used.
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
Exhaust Restrictor # 8
15 feet (4.5m)
Diffuser Open
10 feet (3m)
5 feet (1.5m)
Attach reducer directly to the fireplace.
0 feet
This is considered a
horizontal elbow (it doesn't
matter whether it turns right
or left). It may be a 30°, 45°,
60°, or 90° elbow.
© Travis Industries
Installation
(for qualified installers only)
PB 42 Linear Only
Exhaust Restrictor # 11
Diffuser Open
Exhaust Restrictor # 5
Diffuser Open
PB 42 Linear Only
H2
H1
Horizontal length is calculated by
adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is
considered a
vertical elbow.
4/19/23 - 1453
PB 42 & 54 MV/GSB2/GSR2 Install
33
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet