Vent Configurations for 42 PB ONLY
Minimum Vent Configuration
Use 5x8" Diameter Coaxial Vent
NOTE: Use the included thimble assembly whenever passing through a wall. (use on front and back of wall
penetration). See picture below.
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.
One elbow (30° or 45°) may be used on the horizontal run.
HINT: Use minimum vent kit "H" (96200332) from Travis Industries (additional vent may be required).
PB 42 Linear Only
Elbow Placed Directly on Top of Fireplace
3 feet (0.915m)
0 feet
Use the included wall thimble when
penetrating a wall. Part #250-04833
© Travis Industries
Installation
(for qualified installers only)
Exhaust Restrictor # 1 (stock)
Diffuser Closed (stock)
For 54 PB see page 35
Max. 20' (6M) Horizontal Section(s)
4/19/23 - 1453