80
CoolSmart TV – Mantel Clearances
When using this kit, disregard the combustible mantel requirements in the manual and follow the requirements
shown to the right.
If you wish to place a TV above the mantel, it must meet the following requirements:
Minimum 1" air gap behind TV to wall.
The mantel must extend 2" in front of the TV and 1" to both sides.
47" (1194mm)
46" (1169mm)
45" (1143mm)
44" (1118mm)
43" (1093mm)
42" (1067mm)
41" (1042mm)
Mantel Height
40" (1016mm)
Above Base (a) With
39" (991mm)
CoolSmart TV Kit
38" (966mm)
37" (941mm)
36" (916mm)
35" (890mm)
34" (864mm)
33" (838mm)
32" (813mm)
31" (787mm)
30" (762mm)
29" (737mm)
28" (713mm)
© Travis Industries
Installation
(for qualified installers only)
Maximum Mantel Depth (b) With
CoolSmart TV Kit
b
a
Min.
28-5/8"
ProBuilder
728mm
Fireplace
4/19/23 - 1453
Combustible Facing Allowed
(Min. 28-5/8" 728mm Above
Base of Fireplace)
Non-Combustible
Facing Only
Linear
PB 42 & 54 MV/GSB2/GSR2 Install